Huamei 1470nm Laser Fractional Beauty Equipment for Wrinkle Remover Firm Skin Laser Anti-aging Machine

Product Description

Our Service

  • Professional manufacture with 20 years experience, master the most advantage technologies of medical beauty equipment.
  • Professional R & D team, supply OEM / ODM service. Your logo, outshape, language, interface can specially be designed on your machine.
  • 2 years warranty, lifetime free service and maintenance.
  • Fastest delivery time, we promise arrange delivery within 7 working days.
  • Professional service team, supply 24 hours online service.
Professional Medical Beauty Equipment Service

About Machine Details

  • 1470nm diode laser is a single emitter (Laser power of diode: 2.5 W)
  • The energy density of a single spot: 3.3-200 MJ/cm2
  • Pulse width: 1-60 ms
  • Drive the optical lens through the steering gear to form a 6*6 spot array
  • The size of the spot array: length 9mm * width 9mm
  • The spot array has 6 rows and 6 columns (Row spacing: 1.8mm, Column spacing: 1.8mm)
Diode Laser Machine Details

Shape & Size of Microscopic Treatment Zone (MTZ)

The overall treatment area is square, the overall coverage area is 9mm*9mm, and the formed dot matrix is 6 rows and 6 columns with a single point size of 100um*100um.

MTZ Shape and Size Diagram

Duration of Treatment

Stamping mode, one spot time: 250ms+6*pulse width, depends on the setting of pulse width.

Treatment Duration and Parameters

Temperature & Control Interface

Ambient Temperature: -10°C to 60°C (perfectly suitable for a variety of different working scenarios).
Working Temperature: 15°C to 35°C (we adopt active fan cooling, the highest temperature will reach 35°C during operation).

The controller features an intuitive touch screen control, providing both operation convenience and an elegant look.

Controller Interface Front View
Controller Interface Diagonal View
Controller Interface Setup Screen
Controller Interface Active Screen

How the 1470nm Wrinkle Removal Laser Works

  • Depth of action: MTZ is generally 400um. The greater the energy, the deeper the penetration depth.
  • Mechanism: Creates hundreds of thousands of microscopic treatment areas in the upper layers of the skin, replacing damaged skin with healthy-looking tissue to produce younger-looking skin.

Product Usage Plan

  • Each treatment takes about 30 minutes or less. Significant improvements are typically reported after 4-6 treatments, though regular sessions can be integrated into regular skincare regimens.
  • Within 1 to 2 weeks post-treatment, skin feels softer and looks brighter. Effects can last for several months depending on age, skin condition, and UV protection.

To All Who Love Beauty

Your skin will feel softer, younger and more radiant.

Sun exposure, environmental conditions, and lifestyle factors can cause dull skin regardless of age. Whether seeking to prolong a youthful appearance or address early signs of aging, the 1470nm Wrinkle Remover provides a reliable solution.

Manufacturing Profile & Technology

We are a leading manufacturer of beauty machinery in the industry, focusing on high quality and advanced technology. The equipment is designed to be easy to operate and durable. Our systems have been exported to more than 120 countries and regions worldwide, earning a strong reputation.

Manufacturing Facility Showcase

Experienced

Since 2000, we have developed more than 20 kinds of medical and beauty products.

Product Development History

Independent Research & Development

Independent research and development design, providing customized services.

R&D Department
Technical Design Process

Factory Operations

Own processing workshop ensures product quality control at every stage.

Assembly Workshop

2-Year Warranty

We focus on every customer, providing a highly comprehensive after-sales support system.

Quality Warranty Protection

Frequently Asked Questions

How does the 1470nm Wrinkle Removal Laser work?
The laser works by creating hundreds of thousands of microscopic treatment areas (MTZ) in the upper layers of the skin. This triggers a natural healing process that replaces damaged skin with healthy-looking tissue, producing a younger, softer, and more radiant appearance.
What is the depth and shape of the Microscopic Treatment Zone (MTZ)?
The overall treatment area is square (9mm * 9mm), forming a dot matrix of 6 rows and 6 columns. The single spot size is 100um * 100um. The depth of action is generally 400um; greater energy settings lead to a deeper penetration depth.
What are the temperature parameters and cooling mechanism of the machine?
The equipment operates efficiently in ambient temperatures ranging from -10°C to 60°C. During operation, its active fan cooling system maintains the working temperature between 15°C and 35°C (reaching a peak of 35°C under active load).
What is the recommended treatment plan and duration?
Each session takes approximately 30 minutes or less. Significant skin improvements are generally seen within 1 to 2 weeks after a session, with optimal long-term results achieved after 4-6 treatments. Results can last for several months depending on age and skin protection.
Do you provide custom design and OEM/ODM services?
Yes. Our professional R&D team provides full OEM and ODM services. We can customize the machine's external shape, integrated brand logos, user interface languages, and display screens to meet your specific requirements.
What warranty and after-sales support do you offer?
We offer a comprehensive after-sales system that includes a 2-year warranty and lifetime free service and maintenance. In addition, our professional service team is available online 24 hours a day to provide support.

Related Products